SAP & Testing for Building Regulations

THE BRIEF

  • UK Building Compliance can offer a Complete Package and guidance including SAP & Testing for Building Regulations for New Build properties
SAP & Testing for Building Regulations

THE PROCESS

  • After reviewing drawings, on site testing was ready to be completed. In accordance with our strict air tightness testing, building sound testing and ventilation testing procedures, all calibrated equipment was setup to ensure the most accurate result possible
  • Our consultants guided the client to ensure compliance was met, with the following recommendations:
  • Low U-Value Glazing and an efficient combi boiler
  • A high specification meant that low floor, wall and roof U-Values were achieved
  • Constructive bridging details were used to ensure accurate thermal bridging figures

THE RESULTs

  • AIR TESTING RESULTS

≤ 8.0 m³.h.m² @ 50pa

Flat 1 - Target

≤ 8.0 m³.h.m² @ 50pa

Flat 2 - Target

≤ 8.0 m³.h.m² @ 50pa

Flat 3 - Target

≤ 8.0 m³.h.m² @ 50pa

Flat 4 - Target

  • SOUND TESTING RESULTS

Airborne Floor Target

≥ 45

Flat 2 Lounge/Kitchen - Flat 4 Lounge/Kitchen

≥ 45

Flat 1 Lounge/Kitchen - Flat 3 Lounge/Kitchen

Impact Floor Target

≤ 62

Flat 4 Lounge/Kitchen - Flat 2 Lounge/Kitchen

≤ 62

Flat 3 Lounge/Kitchen - Flat 1 Lounge/Kitchen

  • AVERAGE SAP RATING

≤ 26.00

Average Target Emission Rate (TER)

≤ 69.41

Average Target Fabric Energy Efficiency (TFEE)

7.36

Flat 1 - Result

7.66

Flat 2 - Result

7.66

Flat 3 - Result

7.74

Flat 4 - Result

Airborne Floor Result

46

Flat 2 Lounge/Kitchen - Flat 4 Lounge/Kitchen

46

Flat 1 Lounge/Kitchen - Flat 3 Lounge/Kitchen

Impact Floor Result

59

Flat 4 Lounge/Kitchen - Flat 2 Lounge/Kitchen

60

Flat 3 Lounge/Kitchen - Flat 1 Lounge/Kitchen

25.50

Average Dwelling Emission Rate (DER)

65.55

Average Dwelling Fabric Energy Efficiency (DFEE)

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

  • Compliant
  • Water Usage Calculations of 123.04 Litres per person per day was achieved, the Target being ≤ 125L   
  • All of the Ventilation Tests passed with no problems
  • In addition, an added bonus for taking out our Complete Testing and Certification services is a package discount on our fee   

Please refer to our Myth Busters for SAP Calculations here, Myth Busters for Air Tightness Testing here for common misconceptions and our How To Guides in our Advice Centre here

Start Using UK Building Compliance Today


You may also like

January 25, 2024

July 12, 2022

June 27, 2022

June 23, 2022

May 17, 2022

May 12, 2022

Start Using UK Building Compliance Today