Complete Building Testing Package – Halisham

THE BRIEF

  • We completed Full Building Testing & SAP Certification for this pair of homes in Hailsham, East Sussex
  • To pass an Airborne test for new build properties you must score 45db or higher
  • Airborne tests measure the difference in sound levels between the receiver room and neighbouring walls or floors
  • If the sound output in the receiver room is 100db and the sound leakage being passed through into the neighbouring room is 40db, then the result would be 60 and therefore would be a pass
Complete Building Testing Package - Halisham

THE PROCESS

  • After reviewing drawings, on site testing was ready to be completed. All calibrated equipment was setup in accordance to our strict procedures to ensure the most accurate result possible

THE RESULTs

  • AIR TESTING RESULTS

≤ 5.0 m³.h.m² @ 50pa

Plot 129 - Target

≤ 5.0 m³.h.m² @ 50pa

Plot 131 - Target

  • SOUND TESTING RESULTS

Airborne Wall Target

≥ 45

Plot 129 Bedroom - Plot 131 Bedroom

  • SAP RESULTS

≤ 15.91

Plot 129 - Target Emission Rate (TER)

≤ 15.91

Plot 131 - Target Emission Rate (TER)

≤ 50.4

Plot 129 - Target Fabric Energy Efficiency (TFEE)

≤ 50.5

Plot 131 - Target Fabric Energy Efficiency (TFEE)

4.86

Plot 129 - Result

4.89

Plot 131 - Result

Airborne Wall Result

56

Plot 129 Bedroom - Plot 131 Bedroom

15.72

Plot 129 - Dwelling Emission Rate (DER)

15.72

Plot 131 - Dwelling Emission Rate (DER)

46.2

Plot 129 - Dwelling Fabric Energy Efficiency (DFEE)

45.2

Plot 131 - Dwelling Fabric Energy Efficiency (DFEE)

PASS

PASS

PASS

PASS

PASS

PASS

PASS

  • Compliant
  • All of the Ventilation Tests passed with no problems   
  • Our Full Testing package combined with SAP Certification offers excellent value   

Start Using UK Building Compliance Today


You may also like

January 25, 2024

July 12, 2022

June 27, 2022

June 23, 2022

May 17, 2022

May 12, 2022

Start Using UK Building Compliance Today